Complete Gearbox & Geared Motor Solutions

Technical guide

Industrial Gearbox Installation, Lubrication and First-Run Checklist

Author: HUIGUANG × CHENGFA Transmission Technical Team · Updated: 2026-08-16

CHENGFA machining workshop

Before commissioning, verify the nameplate and rotation, foundation, fasteners, shaft alignment, oil level, lubricant, venting, connected loads and guards. Installation errors can create shaft loads, vibration, leakage and heat even when the gearbox itself is correctly selected.

Follow the equipment safety procedure for a short no-load or low-load check, recording rotation, noise, vibration, leakage and current before loading gradually. Stop if severe noise, rapid heating, major leakage or abnormal current appears. Lubricant type, quantity and maintenance interval must follow the model manual and order documents.

For an installation review, send the model, photographs, connection arrangement and running record to sales@chinfar.com.

Related products